Fire ATS Box
Product Description
Our Fire ATS Box (AT-XF series) is a dedicated dual-power automatic transfer switch solution for fire equipment requiring reliable power supply from mains and fire backup sources with automatic switching to ensure uninterrupted operation of fire fans, fire pumps, and other critical fire systems. Designed specifically for fire protection applications, this box automatically detects mains power failure and transfers the fire equipment load to the fire backup power source (generator or dedicated fire feeder) within seconds, then transfers back when mains power is restored. The fire-specific design includes priority transfer for fire loads, fire alarm signal input for forced transfer to backup power, and status indication for both power sources and transfer position. Built with robust steel enclosures and ATS controllers and breakers from trusted brands, this ATS box ensures reliable power continuity for fire protection systems in commercial buildings, industrial facilities, and public infrastructure. The AT-XF series format offers a proven, code-compliant structure tailored to fire equipment power requirements, making this box ideal for fire fan and pump power backup, critical fire system continuity, and fire code compliance.
Yuanzhuo Electrical Equipment manufactures fire ATS boxes strictly to customer drawings and fire code specifications. Our 12,000 m² facility with five automated production lines and an annual capacity of 10,000 units supports both small and large orders. Each box undergoes 100% powered testing, including transfer function simulation and fire forced-transfer verification, before wooden-crate packaging. We support paid samples with a typical development cycle of about one week, and standard delivery of three weeks to one month.
Specifications
|
Parameter |
Specification |
|
Product Type |
Fire ATS Box |
|
Series |
AT-XF |
|
Rated Voltage |
AC 220V / 380V / 400V |
|
Rated Current |
16A – 1600A (customizable) |
|
Transfer Type |
Automatic (controller-based), 4-pole or 3-pole |
|
Power Sources |
Mains + Fire backup (generator / dedicated feeder) |
|
Key Functions |
Auto transfer, fire forced-transfer, priority load, status indication |
|
Transfer Time |
Typically 1–5 seconds (per controller spec) |
|
Enclosure Material |
Cold-rolled steel, powder-coated |
|
Protection Grade |
IP30 (IP40/IP54 available) |
|
Installation |
Floor-standing or wall-mounted |
|
Component Brands |
Schneider, Siemens, Chint, Delixi (per spec) |
|
Custom Options |
Current rating, transfer logic, fire input, dimensions, branding |
Applications
Fire Fan and Pump Power Backup
Provides automatic dual-power transfer for fire fans, fire pumps, and pressure stabilizing pumps, ensuring these critical fire loads switch to backup power within seconds of mains failure for uninterrupted fire protection.
Critical Fire System Continuity
Serves as the ATS for fire alarm systems, emergency lighting, and fire elevator controls, where reliable power continuity is essential for life safety and the fire forced-transfer function ensures backup power engagement during fire emergencies.
Commercial and Industrial Fire Code Compliance
Delivers code-compliant dual-power transfer for fire protection systems in office buildings, factories, hospitals, and schools, where fire-specific ATS with priority transfer and status indication supports fire safety inspections.
Customization
Customization includes rated current, transfer switch type (circuit breaker or contactor based), pole configuration (3-pole or 4-pole), controller brand and features, fire alarm forced-transfer input, priority load configuration, power source configuration, enclosure dimensions, protection grade, installation type, surface color, and customer branding. We manufacture strictly to confirmed customer drawings and fire code specifications.
Packaging & Transportation
Each box is wrapped in protective film and packed in a wooden crate with internal anti-collision padding. We support FOB to a designated Chinese port and EXW. Payment: 40% deposit, 80% after pre-shipment inspection, full balance at the designated Chinese port. Currencies: USD, EUR, RMB.
FAQ
Q1: What is the difference between a fire ATS and a standard ATS?
A: A fire ATS includes fire-specific features such as fire alarm signal input for forced transfer to backup power (regardless of mains status), priority transfer for fire loads, and fire code-compliant status indication. These features ensure fire equipment receives backup power immediately during fire emergencies, even if mains power is technically available but unreliable.
Q2: Can you customize the current rating and transfer logic?
A: Yes. We customize rated current (16A to 1600A), transfer switch type, pole configuration, fire forced-transfer logic, priority load settings, and enclosure specifications based on your fire equipment power requirements.
Q3: What testing do you perform before shipment?
A: Every box undergoes powered testing, transfer function simulation, fire forced-transfer verification, timing measurement, and protection function testing. We perform 100% inspection and accept third-party inspections.
Hot Tags: fire ats box, China fire ats box manufacturers, suppliers, factory