Power and Distribution Transformers-
Medium and High Voltage Power Distribution Solutions (50 kVA to 20 MVA)
Yuanzhuo Electrical manufactures oil-immersed distribution transformers, cast resin dry-type transformers, and specialized step-up units for global power grids, renewable energy sites, and industrial complexes. Engineered to comply with IEC 60076 and IEEE C57 standards, our transformers deliver stepping-down and stepping-up voltage conversion with low operational losses, high mechanical short-circuit strength, and long service life under fluctuating load conditions.
All units are fabricated, assembled, and tested within our ISO 9001 and ISO 14001 certified manufacturing plant in Jiangsu. Configurations accommodate regional utility grid requirements, varied ambient temperature profiles, and specialized enclosure protection classes.
-
Dry Type Pad Mounted TransformerThe Dry Type Pad Mounted Transformer is a mature product from Yuanzhuo Electrical Equipment. Its core feature is safety. It does not use any insulating oil. We use epoxy resin to cast the coils.view more
-
Immersed TransformerThe Immersed Transformer is a core product from Yuanzhuo Electrical Equipment. We designed it for outdoor and large power applications. Its core uses insulating oil.view more
Technical Specifications and Configuration
|
Parameter |
Oil-Immersed Distribution |
Cast Resin Dry-Type |
Renewable Step-Up |
|
Capacity Range |
50 kVA to 20,000 kVA |
100 kVA to 10,000 kVA |
500 kVA to 12,500 kVA |
|
Primary Voltage Range |
6 kV, 11 kV, 22 kV, 33 kV, up to 35 kV |
6 kV, 11 kV, 22 kV, 33 kV, up to 35 kV |
11 kV, 22 kV, 33 kV, 34.5 kV, 38.5 kV |
|
Secondary Voltage Range |
0.4 kV, 0.415 kV, 0.433 kV, 0.69 kV |
0.4 kV, 0.415 kV, 0.433 kV, 0.69 kV |
0.400 kV to 0.800 kV (Inverter matching) |
|
Frequency |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
|
Vector Group |
Dyn11, Ynd11, Dyn5, Yyn0 (Custom) |
Dyn11, Ynd11, Dyn5, Yyn0 (Custom) |
Dy11y11, Dyn11, Ynd11 |
|
Tap Changer |
Off-Circuit Tap Changer (+/- 2x2.5%) or OLTC |
Off-Circuit Tap Changer (+/- 2x2.5%) |
Off-Circuit Tap Changer or On-Load Tap Changer |
|
Insulation Class |
Class A (105 degrees C) |
Class F (155 degrees C) / Class H (180 degrees C) |
Class A (105 degrees C) or High-Temp Synthetic |
|
Temperature Rise Limit |
65K (Oil) / 70K (Winding) |
100K / 125K (Winding) |
65K or customized for high ambient sites |
|
Impedance Voltage |
4.0% to 8.0% (Standard compliant) |
4.0% to 8.0% |
6.0% to 10.0% |
|
Partial Discharge Level |
N/A (Liquid Filled) |
Less than 10 pC |
Less than 10 pC (if Dry-type) / N/A |
|
Cooling Method |
ONAN / ONAF |
AN / AF (Forced air fans optional) |
ONAN / KNAN (Ester oil) / ONAF |
|
Enclosure Rating |
IP54 / IP55 (Terminal boxes / Tanks) |
IP00 (Unenclosed), IP20, IP23, IP31 |
IP54 / IP55 Compartments |
|
Applicable Standards |
IEC 60076, IEEE C57.12, EN 50588-1 |
IEC 60076-11, IEEE C57.12.01 |
IEC 60076, IEEE C57.12, EN 50588-1 |
Applications and Field Deployment
Municipal Utility Networks:
Power distribution across urban and rural grids requires continuous operation under unbalanced phase loads and lightning surge exposure. Our transformers use multi-layer insulation systems and surge arresters to protect against line transients.
Commercial Buildings & Public Infrastructure:
High-density public structures enforce strict fire safety codes. Our cast resin dry-type series uses F-class self-extinguishing resin matrices that eliminate oil spill hazards and prevent combustion during internal electrical faults.
Heavy Industrial & Mining Plants:
Arc furnaces, rolling mills, and mining machinery subject transformers to harmonic distortion, cyclic overload, and high vibration. Our heavy-duty core clamping and reinforced tanks maintain structural rigidity and low vibration noise under high dynamic stresses.
Solar PV & Energy Storage Substation Integration:
Inverter-duty step-up transformers must handle non-sinusoidal current waveforms and bidirectional power flows. We build dual-secondary winding transformers with grounded electrostatic shielding between primary and secondary layers to prevent high-frequency inverter noise propagation into the utility grid.
OEM and ODM Customization Options

Mechanical & Physical Customization
Tank Design: Choice between corrugated radiator tanks for compact distribution units or heavy tubular radiator banks with detachable maintenance valves for larger power units.
Terminal Arrangement: Top-mounted porcelain / polymeric bushings, side-entry cable boxes with removable gland plates, or direct busduct flange interfaces.
Surface Coating Systems: Multi-coat paint systems including zinc-rich primers and epoxy / polyurethane topcoats tested for C3, C4, or C5-M marine anti-corrosion environments according to ISO 12944.
Electrical & Operational Engineering
Custom Voltage Ratios & Dual Voltages: Primary windings equipped with dual-voltage switching mechanisms (such as 11 kV / 22 kV switchable) to support expanding distribution networks.
Special Loss Requirements: Custom core stacking using high-grade domain-refined CRGO steel to meet strict low-loss energy efficiency standards (such as EU Tier 2 EcoDesign or US DOE loss limits).
Monitoring & Protection Accessories: Factory integration of magnetic oil level gauges, winding / oil temperature indicators (WTI / OTI) with RS485 contacts, Buchholz relays, pressure relief valves, and online DGA (Dissolved Gas Analysis) sensors.

Manufacturing Quality Control and Testing

Raw Material Validation: CRGO steel sheets undergo magnetic permeability and core-loss verification. Electrolytic copper coils are tested for conductivity and dimensional tolerances. Insulating oils are tested for breakdown voltage (BDV greater than 60 kV), moisture content, and dielectric dissipation factor.
Core Stacking & Winding Precision: Automatic core shearing lines ensure burr-free lamination edges to reduce eddy current losses. Computer-controlled coil winding machines maintain precise tensioning and turn counts, followed by vacuum drying cycles to remove moisture prior to oil impregnation or resin casting.
Type and Special Testing (Upon Request): Temperature rise tests, full-wave lightning impulse voltage withstand tests (BIL), noise level measurements (IEC 60076-10), and short-circuit withstand verification reports issued by independent testing bodies.
Routine Testing (100% of Produced Units): Every unit undergoes the following routine factory tests according to IEC 60076-1:
- Measurement of winding resistance
- Measurement of voltage ratio and phase displacement (Vector Group check)
- Measurement of short-circuit impedance and load loss (Pk)
- Measurement of no-load loss (P0) and no-load current
- Separate-source AC withstand voltage test (Applied Voltage Test)
- Induced overvoltage withstand test (DVWV)
- Partial discharge measurement (for all Cast Resin Dry-Type units)
- Transformer oil breakdown voltage and moisture content test

Export Packaging, Documentation and Logistics
Oil-Immersed Units: Transported filled with dielectric oil or nitrogen-padded for large units. Nitrogen-filled units are fitted with pressure monitoring gauges during transit.
Dry-Type Units: Sealed inside heavy-gauge polyethylene vapor barriers with industrial desiccant packets, protected by internal structural bracing.
Exterior Crate: ISPM 15 heat-treated solid wooden crates or steel-skid frames with reinforced corner posts and skid bases for heavy lifting.
Attached inside a weatherproof sleeve on each unit:
Certified Factory Routine Test Report detailing exact measured losses, impedances, and insulation resistance matching the unit serial number.
Final General Arrangement (GA) Drawing, Nameplate Drawing, and Electrical Schematic Diagrams.
Installation, Operation, and Maintenance Manual (English standard).
CE Declaration of Conformity and Factory Quality Inspection Certificates.
Supported Incoterms: EXW, FOB Ningbo / Shanghai, CIF, CFR, DDP.
Logistics Execution: Standard containerization (20GP / 40GP / 40HQ) for small-to-mid distribution units; Open-Top, Flat-Rack, or Break-Bulk shipping for high-capacity power transformers.
FAQ

Request a Technical Proposal and Factory Quotation
Need detailed single-line diagrams (SLD), dimensional GA drawings, loss datasheets, or factory-direct pricing for an upcoming power project or tender?
Contact our engineering team with your project parameters:
Primary Technical Parameters Needed: Rated Capacity (kVA/MVA), Primary & Secondary Voltages (kV), Vector Group, Tap-Changer Type (Off-Load or OLTC), Installation Environment (Indoor/Outdoor), and Target Loss Standards (such as IEC, EU EcoDesign, IEEE).
Direct Sales & Engineering Office: Yuanzhuo Electrical Equipment (Jiangsu) Co., Ltd.
Factory Address: Group 8, Chengdong Village, Fucheng Sub-district Office, Funing County, Jiangsu Province, China
Technical Quotation Email: mark.yzpower@gmail.com
Engineering Hotline / WhatsApp: +86 130 1284 2666 / +86 190 5157 1560
We're well-known as one of the leading transformer manufacturers and suppliers in China. We warmly welcome you to wholesale high quality transformer at competitive price from our factory. If you have any enquiry about cooperation, please feel free to email us.
Dry Type Pad Mounted Transformer, transformer, Immersed Transformer