Smoke Exhaust Fan Control Box
Product Description
Our Smoke Exhaust Fan Control Box (PY-FJ series) is a dedicated control solution for building smoke exhaust system fans requiring fire damper linkage, overload protection, and fire forced-start capability. Designed specifically for fire smoke exhaust applications, this box provides fan motor control, circuit protection, fire alarm interface, and fire damper interlock in a compact enclosure. The fire damper linkage function automatically shuts down the fan when the damper closes due to high temperature, preventing fire spread through the ductwork. The fire forced-start function overrides normal controls to activate the fan during fire emergencies, ensuring smoke extraction when needed most. Built with robust steel enclosures and control components from Schneider, Siemens, Chint, and Delixi, this control box ensures reliable smoke exhaust fan operation for commercial buildings, parking garages, and public facilities. The PY-FJ series format offers a proven, code-compliant structure tailored to smoke exhaust system requirements, making this box ideal for fire smoke exhaust fans, ductwork smoke control, and fire safety systems.
Yuanzhuo Electrical Equipment manufactures smoke exhaust fan control boxes strictly to customer drawings and fire code specifications. Our 12,000 m² facility with five automated production lines and an annual capacity of 10,000 units supports both small and large orders. Each box undergoes 100% powered testing, including fire damper linkage simulation and forced-start verification, before wooden-crate packaging. We support paid samples with a typical development cycle of about one week, and standard delivery of three weeks to one month.
Specifications
|
Parameter |
Specification |
|
Product Type |
Smoke Exhaust Fan Control Box |
|
Series |
PY-FJ |
|
Rated Voltage |
AC 220V / 380V / 400V |
|
Motor Power |
0.75kW – 75kW (customizable) |
|
Key Functions |
Fire damper linkage, fire forced-start, overload protection |
|
Control Modes |
Manual/auto, fire linkage, status indication |
|
Protection |
Overload, short circuit, phase loss (per spec) |
|
Enclosure Material |
Cold-rolled steel, powder-coated |
|
Protection Grade |
IP54 (IP65 available) |
|
Installation |
Wall-mounted or floor-standing |
|
Component Brands |
Schneider, Siemens, Chint, Delixi (per spec) |
|
Custom Options |
Motor power, damper linkage, dimensions, branding |
Applications
Building Smoke Exhaust Systems
Provides dedicated control for smoke exhaust fans in office buildings, shopping malls, and hotels, where fire damper linkage and forced-start functions ensure reliable smoke extraction during fire emergencies.
Parking Garage Ventilation and Smoke Control
Serves as the control box for smoke exhaust fans in underground and enclosed parking garages, where the dual function of daily ventilation and emergency smoke exhaust requires robust control with fire safety features.
Commercial Kitchen and Industrial Smoke Extraction
Delivers reliable control for smoke extraction fans in commercial kitchens and industrial facilities, where fire damper linkage prevents fire spread through ductwork and overload protection ensures continuous operation.
Customization
Customization includes motor power rating, control method (direct-on-line, star-delta, soft starter), fire damper linkage input configuration, fire forced-start logic, manual/auto selector type, overload and protection settings, enclosure dimensions, protection grade, installation type, surface color, and customer branding. We manufacture strictly to confirmed customer drawings and fire code specifications.
Packaging & Transportation
Each box is film-wrapped and packed in a wooden crate with internal anti-collision padding. We support FOB to a designated Chinese port and EXW. Payment: 40% deposit, 80% after pre-shipment inspection, full balance at the designated Chinese port. Currencies: USD, EUR, RMB.
FAQ
Q1: What is the fire damper linkage function?
A: The fire damper linkage automatically shuts down the smoke exhaust fan when the fire damper in the ductwork closes due to high temperature (typically 280°C), preventing fire and smoke from spreading through the duct system. This is a required safety function for smoke exhaust systems.
Q2: Does this box support fire forced-start?
A: Yes. The fire forced-start function overrides normal control logic to activate the fan during fire emergencies, ensuring smoke extraction operates when commanded by the fire alarm system, regardless of normal control settings.
Q3: What is the delivery time?
A: Depending on specification and quantity, standard delivery is typically three weeks to one month.