Fire Pump Control Box

Fire Pump Control Box

Details
Our Fire Pump Control Box (XFK-B series) is a dedicated control solution for fire hydrant pumps and sprinkler pumps requiring reliable start/stop control with fire linkage, pressure automatic control, and manual/auto switching. Designed for building fire water supply systems, this box provides pump motor control, circuit protection, pressure monitoring, fire alarm interface, and status indication in a compact enclosure.
Category
Fire Fighting System Control Box
Share to
Send Inquiry
Description
Technical Parameters

Fire Pump Control Box

Product Description

Our Fire Pump Control Box (XFK-B series) is a dedicated control solution for fire hydrant pumps and sprinkler pumps requiring reliable start/stop control with fire linkage, pressure automatic control, and manual/auto switching. Designed for building fire water supply systems, this box provides pump motor control, circuit protection, pressure monitoring, fire alarm interface, and status indication in a compact enclosure. The pressure automatic control function starts the pump when system pressure drops below the set threshold and stops it when pressure is restored, ensuring consistent fire water supply pressure. The fire linkage function enables pump activation from the fire alarm system or manual fire alarm call points, while the manual/auto selector allows local control for maintenance and testing. Built with robust steel enclosures and control components from Schneider, Siemens, Chint, and Delixi, this control box ensures reliable fire pump operation for commercial buildings, industrial facilities, and public infrastructure. The XFK-B series format offers a proven, code-compliant structure tailored to fire pump requirements, making this box ideal for fire hydrant systems, sprinkler systems, and fire water supply control.

 

Yuanzhuo Electrical Equipment manufactures fire pump control boxes strictly to customer drawings and fire code specifications. Our 12,000 m² facility with five automated production lines and an annual capacity of 10,000 units supports both small and large orders. Each box undergoes 100% powered testing, including pressure control simulation and fire linkage verification, before wooden-crate packaging. We support paid samples with a typical development cycle of about one week, and standard delivery of three weeks to one month.

 

Specifications

Parameter

Specification

Product Type

Fire Pump Control Box

Series

XFK-B

Rated Voltage

AC 220V / 380V / 400V

Motor Power

1.5kW – 160kW (customizable)

Control Functions

Start/stop, fire linkage, pressure auto control, manual/auto

Control Methods

Direct-on-line, star-delta, soft starter, auto-coupling (per spec)

Protection

Overload, short circuit, phase loss, under-voltage (per spec)

Enclosure Material

Cold-rolled steel, powder-coated

Protection Grade

IP54 (IP65 available)

Installation

Wall-mounted or floor-standing

Component Brands

Schneider, Siemens, Chint, Delixi (per spec)

Custom Options

Motor power, control method, pressure setpoint, dimensions, branding

 

Applications

 
 

Fire Hydrant Systems

Provides dedicated control for fire hydrant pumps in commercial and industrial buildings, where pressure automatic control and fire linkage ensure immediate water supply when hydrants are activated during fire emergencies.

 
 
 

Sprinkler Systems

Serves as the control box for fire sprinkler pumps in offices, warehouses, and retail facilities, where reliable pump activation upon pressure drop ensures rapid water delivery to sprinkler heads for fire suppression.

 
 
 

Fire Water Supply for Industrial and Public Facilities

Delivers reliable fire pump control for factories, hospitals, schools, and transportation hubs, where code-compliant fire water supply with manual/auto modes and status indication supports fire safety inspections and emergency response.

 

 

Customization

Customization includes motor power rating, control method (direct-on-line, star-delta, soft starter, auto-coupling), pressure sensor and setpoint configuration, fire linkage input, manual/auto selector, overload and protection settings, enclosure dimensions, protection grade, installation type, surface color, and customer branding. We manufacture strictly to confirmed customer drawings and fire code specifications.

 

Packaging & Transportation

Each box is film-wrapped and packed in a wooden crate with internal anti-collision padding. We support FOB to a designated Chinese port and EXW. Payment: 40% deposit, 80% after pre-shipment inspection, full balance at the designated Chinese port. Currencies: USD, EUR, RMB.

 

FAQ

Q1: What control methods do you support for fire pumps?

A: We support direct-on-line, star-delta, soft starter, and auto-coupling (reduced-voltage) starting methods based on your pump motor power and electrical system capacity. The control method is selected to ensure reliable pump starting without excessive voltage drop.

Q2: Does this box support pressure automatic control?

A: Yes. The pressure automatic control function monitors fire water system pressure and automatically starts the pump when pressure drops below the set threshold, stopping it when pressure is restored. The pressure setpoint is fully customizable based on your system requirements.

Q3: What testing do you perform before shipment?

A: Every box undergoes powered testing, pressure control simulation, fire linkage verification, start/stop function testing, and protection function verification. We perform 100% inspection and accept third-party inspections.

 

Hot Tags: fire pump control box, China fire pump control box manufacturers, suppliers, factory

Send Inquiry
Contact usif have any question

Jiangsu Yuanzhuo Electric Power Equipment Co., Ltd. is a medium-sized enterprise specializing in the R&D, production, sales, and service of high and low voltage switchgear cabinets.

Contact now!